Trouble-free (U)HPLC connections every time

This connection system is recommended for all connections in a standard AZURA Analytical system. It incorporates flexible 1/32” OD tubing to easily route through your system. The fitting is already installed on each capillary.

Capillary type ID [mm] Length [mm] Recommended for connection Recommended for System Order No.
MarvelXACTTM SST 0.254 150   HPLC 862 bar / classical HPLC AZF121
MarvelXACTTM SST 0.254 250   HPLC 862 bar / classical HPLC AZF122
MarvelXACTTM SST 0.254 350   HPLC 862 bar / classical HPLC AZF123
MarvelXACTTM SST 0.254 500   HPLC 862 bar / classical HPLC AZF124
MarvelXACTTM SST 0.254 600 Pump - Autosampler, all systems with 1 AZURA L detector UHPLC / ULDC / HPLC 862 bar / classical HPLC AZF125
MarvelXACTTM SST 0.125 150   HPLC 862 bar / UHPLC AZF111
MarvelXACTTM SST 0.125 250   HPLC 862 bar / UHPLC AZF112
MarvelXACTTM SST 0.125 350 Column - Detector / Detector 1 - Detector 2 HPLC 862 bar / UHPLC AZF113
MarvelXACTTM SST 0.125 500 Autosampler - Column 150 mm length / Column - Detector HPLC 862 bar / UHPLC AZF114
MarvelXACTTM SST 0.125 600 Autosampler - Column 250 mm length HPLC 862 bar / UHPLC AZF115
MarvelXACTTM SST 0.1 150   UHPLC / ULDC AZF101
MarvelXACTTM SST 0.1 250   UHPLC / ULDC AZF102
MarvelXACTTM SST 0.1 350 Column - Detector / Detector 1 - Detector 2 UHPLC / ULDC AZF103
MarvelXACTTM SST 0.1 500 Autosampler - Column 150 mm length / Column - Detector UHPLC / ULDC AZF104
MarvelXACTTM SST 0.1 600 Autosampler - Column > 250 mm length UHPLC / ULDC AZF105
MarvelXACTTM Peek-Lined SST 0.075 500 Autosampler - Column 150 mm length / Column - Detector (UHPLC and ULDC) UHPLC / ULDC AZF05
MarvelXACTTM Peek-Lined SST 0.075 350 Column - Detector (UHPLC and ULDC) / Detector 1 - Detector 2 UHPLC / ULDC AZF05-1
MarvelXACTTM Peek-Lined SST 0.075 600   UHPLC / ULDC AZF05-2
Flexible SST capillary 0.18 900 Pump - Autosampler, all systems with 2 AZURA L detectors or for benchtop installation UHPLC / ULDC / HPLC 862 bar / classical HPLC AZF55-1

Choose the right K-Connect capillary for your system solution

K-Connect capillaries are flexible stainless steel capillaries with 1/16" sleeves at the ends for easy installation to any standard analytical HPLC port. A wide range of inner diameters and lengths are available. These capillaries are precut for easy handling.

Article number Color code ID [mm] length [mm] Recommended for system Recommended for connection of
AZF41 red 0.10 150 UHPLC Filters in the system, column selection valves and columns
AZF42 red 0.10 300 UHPLC Pump and manual injection valve, detector 1 and detector 2
AZF43 red 0.10 400 UHPLC Column and detector, manual injection valve and column
AZF44 red 0.10 700 UHPLC Autosampler and column, pump and autosampler (only 1 detector in between)
AZF45 red 0.10 900 UHPLC Pump and autosampler (2 detectors in between)
           
AZF51 yellow 0.18 150 HPLC Plus/ classical HPLC Filters in the system, column selection valves and columns 
AZF52 yellow 0.18 300 HPLC Plus/ classical HPLC Pump and manual injection valve, detector 1 and detector 2
AZF53 yellow 0.18 400 HPLC Plus/ classical HPLC Column and detector, manual injection valve and column
AZF54 yellow 0.18 700 HPLC Plus/ classical HPLC Autosampler and column, pump and autosampler (only 1 detector in between)
AZF55 yellow 0.18 900 HPLC Plus/ classical HPLC P 6.1L and AS6.1L when more detectors are placed in between
           
AZF61 black 0.45 150 classical HPLC/ Compact system Filters in the system, column selection valves and columns
AZF62 black 0.45 300 classical HPLC/ Compact system Pump and manual injection valve, detector 1 and detector 2
AZF63 black 0.45 400 classical HPLC/ Compact system Column and detector, manual injection valve and column
AZF64 black 0.45 700 classical HPLC/ Compact system Autosampler and column, pump and autosampler (only 1 detector in between)
AZF65 black 0.45 900 classical HPLC/ Compact system Pump and autosampler (2 detectors in between)

Standard capillaries, stainless steel

These capillaries can be cut by the user with a capillary cutter.
For easier handling and safely precut capillaries, we recommend to use K-Connect capillaries.

Article number OD ID [mm] length [cm] Amount
A0130 1/16" 0.10 300 1
A0131 1/16" 0.25 300 1
A0132 1/16" 0.50 300 1
A0133 1/16" 0.70 300 1
A0134 1/16" 1.00 300 1
A0123 1/16" 0.10 10 10
A0124 1/16" 0.10 20 10
A0125 1/16" 0.10 30 10
A0126 1/16" 0.25 10 10
A0127 1/16" 0.25 20 10
A0128 1/16" 0.25 30 10
A0639 1/8" 1.60 150 1
A0639-4 1/8" 1.60 100 1
A0639-5 1/8" 1.60 150 1
A0639-6 1/8" 1.60 200 1
A0640 1/8" 2.20 150 1
A0640-4 1/8" 2.20 100 1
A0640-5 1/8" 2.20 150 1
A0640-6 1/8" 2.20 200 1
A01322 1/4" 4.60 ca. 500 1
A01322-4 1/4" 4.60 100 1
A01322-5 1/4" 4.60 150 1
A01322-6 1/4" 4.60 200 1

Standard capillaries, PEEK

PEEK capillaries come in a variable length and can be cut by the user with a tube cutter.
Please note the maximum backpressure that can be applied.

Article number Color code OD ID [mm] tolerance max. pressure [bar]
A2522 red striped 1/16" 0.13 Standard Tolerance +/- 0.05 mm (OD and ID) 420
A2523 yellow striped 1/16" 0.18 Standard Tolerance +/- 0.05 mm (OD and ID) 400
A2523-2 yellow striped 1/16"  0.18  Low Tolerance +/- 0.025 mm (OD and ID) 400
A2524 blue striped 1/16" 0.25 Standard Tolerance +/- 0.05 mm (OD and ID) 385
A2525 orange striped 1/16" 0.5 Standard Tolerance +/- 0.05 mm (OD and ID) 350
A2526 green striped 1/16" 0.75 Standard Tolerance +/- 0.05 mm (OD and ID) 240
A2527 grey striped 1/16" 1.0 Standard Tolerance +/- 0.05 mm (OD and ID) 165
A2528 black striped 1/16" 1.4 Standard Tolerance +/- 0.05 mm (OD and ID) 50
A2540 natural 1/8" 1.59 Standard Tolerance +/- 0.05 mm (OD and ID) 220
A2541 natural 1/8" 0.75 Standard Tolerance +/- 0.05 mm (OD and ID) 345
A2542 natural 1/8" 2.0 Standard Tolerance +/- 0.05 mm (OD and ID) 165

PTFE, Tefzel, PFA and ETFE tubing

Article number Material OD ID [mm] Length [cm] max. pressure [bar]
A0182-1 Tefzel® 1/16" 0.25-0.3 variable 185
A0183-1   0.7 variable 115
A01831   0.7 1000 115
A04781-1   1.0 variable 85
A0478-1 Tefzel® 1/8" 1.6 variable 70
A0152-1 PTFE 1/16" (1.6 mm) 0.45 variable 150
A04782-1 1/16" (1.6 mm) 0.9 variable n/a
A0153-1 2 mm 1.5 variable < 10
A0732-1 1/8" (3.2 mm) 1.5 variable 35
A0873-1 3 mm 2.0 variable n/a
A0154-1 4 mm 3.0 variable 20
A1099-1 9 mm 7.0 variable n/a
A3306 PTFE Antistatic
Explosion-Proof
1/8" (3.2 mm) 1.6 mm (1/16") variable 35
A3307 1/4" 4.35  variable 10
A0691A FEP 1/16" 0.5 150 95
A31891 PFA 1/4" 3.96 variable 15.4
A31892 1/8" 1/16" variable 24.2

All trade names and registered trademarks are the property of their respective owners.

Need a quote?

Or just more information about our products?

Please send us your request.
We are happy to answer your questions about our products and services.

 

+49 30 809727 0

Monday to Friday
 7 am- 5 pm CET

sales@knauer.net

Available for you anytime

Follow us on: